System
|
Date/Time
|
FracSec
|
Event
|
Event Subtype
|
Category
|
Area
|
Node
|
Unit
|
Module
|
Module Desc
|
Attribute
|
State
|
Event Level
|
Desc 1
|
Desc 2
|
SHP Unit DeltaV
|
2018-10-11 10:25:44
|
5951 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3428 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3434 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3437 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3445 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3941 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
3970 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4017 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4038 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4052 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4057 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4064 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4951 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4957 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:43
|
4959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/AI1 |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
3985 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
4937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
5441 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
5944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
5945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
9962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:41
|
9964 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
3455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
3456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4048 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4049 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4468 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4469 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4938 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4964 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4965 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4966 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5446 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5931 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5934 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
5949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
8928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
8934 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
8945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
8949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
8960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:40
|
9928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
5948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
5949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
8974 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
8975 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
9458 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:39
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:38
|
3427 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:38
|
3435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:38
|
3439 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:38
|
3444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:38
|
3447 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3936 |
ALARM |
|
HARDWARE |
AREA_A |
CNTR01 |
|
CNTR01 |
Rig Controller |
MAINT_ALM |
ACT/UNACK |
11-WARNING |
MAINT |
[MULT]IO: No Communications On Port - Serial Card, C01, P01 |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3954 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3971 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3974 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
3983 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4040 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4051 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4054 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4059 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4062 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4448 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4461 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4464 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7997 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4468 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
EVENT_LIMITED. |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4953 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4956 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
EVENT_LIMITED. |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5427 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5430 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5433 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5437 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
EVENT_LIMITED. |
4-INFO |
TI102/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5927 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5931 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5934 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
5950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
9455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
9460 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
9949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:37
|
9968 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:07
|
3936 |
ALARM |
|
HARDWARE |
AREA_A |
CNTR01 |
|
CNTR01 |
Rig Controller |
MAINT_ALM |
ACT/UNACK |
11-WARNING |
MAINT |
IO: No Communications On Port - Serial Card, C01, P02 |
SHP Unit DeltaV
|
2018-10-11 10:25:06
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:06
|
3985 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
3989 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
4937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
8929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
8935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
8947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
8950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
8958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
9457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
9959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:05
|
9962 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
3989 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
4939 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
8928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
8934 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
8947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
8950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
8960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
9457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
9461 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:04
|
9928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
3988 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
3989 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
4939 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
8930 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
8936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
8947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
8950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
8959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
9460 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
9462 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:03
|
9928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
8929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
8935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
8946 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
8950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
8958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:02
|
9965 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
3989 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
3990 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
4937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
9459 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
9461 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
9960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:01
|
9963 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
3988 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
4938 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
8930 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
8935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
8947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
8950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
8959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
9456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
9461 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:25:00
|
9926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
9926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
3986 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
4937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
8929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
8935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
8946 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
8949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:59
|
8959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
4937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
8927 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
8933 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
8944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
8948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
8956 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
9456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
9458 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:58
|
9927 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
3454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
3456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
3992 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
3993 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4067 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4069 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4471 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4473 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4939 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4965 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4968 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
4969 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5441 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5942 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
8968 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/WIFI_S7_TEMP_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:57
|
9926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
3448 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
3450 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/MAINT_STATE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
3453 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
3455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OPERATING_STATE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
3994 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4012 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4016 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4021 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4037 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4447 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4460 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4464 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7997 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4467 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
EVENT_LIMITED. |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4952 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4956 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
4962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
EVENT_LIMITED. |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5427 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5430 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5434 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5438 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
EVENT_LIMITED. |
4-INFO |
TI102/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5932 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:55
|
5950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
3460 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
8929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
8935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
8946 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
8949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
8959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
9456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
9460 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:54
|
9925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
3426 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
3434 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
3437 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
3442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
3445 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
9950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:53
|
9969 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
3454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
3455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
4936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
9960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:52
|
9963 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
3985 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4063 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4064 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4469 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4470 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4938 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4964 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4965 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4966 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5440 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5941 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
9458 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:51
|
9925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:49
|
5926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:49
|
5930 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:49
|
5933 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:49
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:49
|
5948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:48
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:48
|
5944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
3937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
3943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
3954 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
3958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
3966 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
4926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
9454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
9458 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
9946 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
9958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:46
|
9964 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
4926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
8974 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
8975 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
9457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
9460 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:45
|
9936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:44
|
9936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:44
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:44
|
9962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:44
|
9964 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:37
|
3427 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:37
|
3432 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:37
|
3436 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:37
|
3443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:37
|
3446 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
3936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
3942 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
3954 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
3957 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
3966 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
4926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
5926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
5929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
5933 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
5950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
9454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
9944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
9957 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:36
|
9966 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
3986 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/WIFI_S7_1200_IN |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4001 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4009 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4012 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4044 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4048 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
4925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
5942 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
8975 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
8977 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
9458 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:35
|
9936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
3454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
3456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
4047 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
4048 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
4925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
8967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/WIFI_S7_TEMP_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:34
|
9937 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
4956 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
4958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/AI1 |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
5434 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
5435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/AI1 |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
8979 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9959 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:33
|
9962 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3426 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3432 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3440 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3445 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
4006 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
4009 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
4014 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:32
|
4017 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
3456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
3457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
3984 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
3986 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
4063 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
4064 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
4925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
4962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
4964 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
8926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
8932 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
8944 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
8947 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
8957 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
9457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
9945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/REGISTER_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
9956 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
TI905/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:31
|
9963 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:30
|
9936 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:30
|
9960 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:30
|
9962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:30
|
9963 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI905 |
Phoenix Contact TC 01 |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:25
|
3426 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:25
|
3432 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:25
|
3435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:25
|
3440 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:25
|
3444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4004 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4008 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4013 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4016 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4448 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4464 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4467 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7997 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4470 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
EVENT_LIMITED. |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4950 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4954 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
4964 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
EVENT_LIMITED. |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5425 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5428 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5431 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5441 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
EVENT_LIMITED. |
4-INFO |
TI102/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5933 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
5948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
9456 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
TI904/AI1/ALM1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:24
|
9460 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
ACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
3453 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
3454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
3986 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
3988 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4056 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4058 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4469 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4471 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4938 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4964 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4965 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
4968 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5440 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5442 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5444 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Module Failure Active |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5942 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
8928 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_0 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
8934 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/DIGITAL_IN_1 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
8945 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_0_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
8949 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
CNTR01_HOLD/BC01_AI2/REGISTER_1_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
8958 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
EVENT_LIMITED. |
4-INFO |
CNTR01_HOLD/S7PL_WATCHDOG_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
9457 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
9459 |
ALARM |
|
INSTRUMENT |
BOILER |
CNTR01 |
|
TI904 |
S7 1200 Wireless Temperature |
PVBAD_ALM |
INACT/UNACK |
15-CRITICAL |
IOF |
General I/O Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:23
|
9925 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
AI200/RAW_INPUT |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3426 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3432 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3440 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_01/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3443 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_01/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
3990 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4009 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4012 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/OWNSTATE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4017 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
S7_RIO_02/COMP_STATE_01 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4020 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
EVENT_LIMITED. |
4-INFO |
S7_RIO_02/COMP_STATE_02 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4448 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/RL_DEV_ONLINE |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4461 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4465 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7997 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4468 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
EVENT_LIMITED. |
4-INFO |
BUS_COUPLER_01/STATUS_REG_7996 |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4953 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4957 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4961 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
TI101/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
4967 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
EVENT_LIMITED. |
4-INFO |
TI101/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5425 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5428 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5431 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5435 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
ACTIVE |
4-INFO |
TI102/MODBUS_IN |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5441 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI102 |
Server Cabinet temperature |
|
EVENT_LIMITED. |
4-INFO |
TI102/AI1 |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5926 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5929 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/ERROR_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5933 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/MEASURE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5943 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
ACTIVE |
4-INFO |
PR9202_1/RL_DEVICE_STATUS |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:21
|
5948 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
PR9202_1 |
HiHi Switch |
|
EVENT_LIMITED. |
4-INFO |
PR9202_1/RL_DEVICE_ONLINE |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
3454 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
3455 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_01 |
Siemens ET200S Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
3985 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
3987 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
CNTR01_HOLD |
Controller 01 holding Module |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4051 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4053 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
S7_RIO_02 |
Siemens ET200SP Remote IO Via Red Lion |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4467 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4468 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
BUS_COUPLER_01 |
Phoenix Contact Remote IO |
|
ACTIVE |
4-INFO |
Error Cleared |
Outputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4935 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
AI200 |
Workshop General Analogue in |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4962 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
I/O Input Failure |
SHP Unit DeltaV
|
2018-10-11 10:24:20
|
4963 |
EVENT |
|
PROCESS |
BOILER |
CNTR01 |
|
TI101 |
Unit External Temperature |
|
ACTIVE |
4-INFO |
Error Cleared |
Inputs Transfer Failure |