Event List (683188)

System Date/Time FracSec Event Event Subtype Category Area Node Unit Module Module Desc Attribute State Event Level Desc 1 Desc 2
SHP Office DeltaV 2022-12-30 14:02:25 3977 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:25 4469 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:24 1478 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-30 14:02:24 1485 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:24 7990 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:23 3973 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:23 4469 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 14:02:22 7987 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-30 10:31:38 7590 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C09, CH08
SHP Unit DeltaV 2022-12-30 10:31:36 7595 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C06, CH04
SHP Unit DeltaV 2022-12-30 10:31:05 3920 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 completed successfully
SHP Unit DeltaV 2022-12-30 10:30:51 7930 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 completed successfully
SHP Unit DeltaV 2022-12-30 10:30:49 7210 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 started
SHP Unit DeltaV 2022-12-30 10:30:36 7602 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C06, CH04
SHP Unit DeltaV 2022-12-30 10:30:35 5915 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-30 10:30:35 8460 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 started
SHP Unit DeltaV 2022-12-30 10:30:34 3970 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator Start of Download - 0
SHP Unit DeltaV 2022-12-30 10:30:34 4810 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator End of download. - 0
SHP Unit DeltaV 2022-12-30 10:30:34 8364 DOWNLOAD USER AREA_A CNTR01 CNTR01 UPDATE Administrator Start of Download - 0
SHP Unit DeltaV 2022-12-30 10:30:34 9072 DOWNLOAD USER AREA_A CNTR01 IO1/C06 UPDATE Administrator Partial Download of I/O Card
SHP Unit DeltaV 2022-12-30 10:30:34 9715 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-30 10:30:34 9931 DOWNLOAD USER AREA_A CNTR01 CNTR01 UPDATE Administrator End of download. - 0
SHP Unit DeltaV 2022-12-30 10:25:02 7571 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C09, CH08
SHP Unit DeltaV 2022-12-30 10:21:16 9710 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2022-12-29 17:29:04 1230 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:04 1725 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:04 8738 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 17:29:04 8740 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:03 5244 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:00 1232 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:00 1728 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:29:00 8736 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 17:29:00 8743 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 17:28:59 5245 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:04 1110 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 10:47:04 1112 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:03 3599 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:03 4094 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:02 1114 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 10:47:02 1122 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:02 7612 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:01 3599 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:01 4092 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:47:00 7612 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:58 1283 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 10:18:58 1284 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:57 3774 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:57 4266 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:56 7788 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:54 1279 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 10:18:54 1286 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:53 3772 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:53 4265 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 10:18:52 7785 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-28 23:32:19 1064 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-28 23:32:07 4151 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 23:31:47 4149 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 23:31:43 4639 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-28 20:27:08 6217 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 20:27:08 6219 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:07 2718 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:07 8706 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:07 9195 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:06 6210 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 20:27:06 6216 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:05 2721 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:05 8703 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 20:27:05 9199 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:15 852 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:15 1347 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:15 8359 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 14:27:15 8361 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:14 4864 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:13 851 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:13 1345 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:13 8357 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 14:27:13 8363 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:27:12 4864 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:33 948 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:33 1442 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:33 8455 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 14:07:33 8457 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:32 4960 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:29 950 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:29 1440 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:29 8453 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 14:07:29 8459 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 14:07:28 4962 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-28 13:51:15 3577 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-28 13:51:07 358 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 13:50:47 365 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 13:50:39 7261 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-27 23:27:47 4747 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-27 23:27:36 4792 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 23:27:16 4803 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 23:27:11 8296 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-27 12:53:15 6585 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-27 12:53:06 729 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 12:52:46 742 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 12:52:40 135 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-27 00:09:36 2562 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-27 00:09:25 6133 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 00:09:05 6139 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 00:09:00 6242 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-26 18:03:57 3858 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-26 18:03:57 3860 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:56 363 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:56 6352 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:56 6844 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:55 3856 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-26 18:03:55 3863 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:54 368 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:54 6352 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 18:03:54 6844 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:47 5258 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-26 13:46:47 5260 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:46 1764 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:46 7751 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:46 8245 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:44 5270 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-26 13:46:44 5277 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:43 1762 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:43 7749 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 13:46:43 8244 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:18 3140 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-25 14:03:18 3141 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:17 5632 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:17 6126 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:16 3138 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-25 14:03:16 3144 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:16 9645 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:15 5635 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:15 6125 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 14:03:14 9645 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:18 5744 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-25 06:22:18 5746 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:17 2248 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:17 8233 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:17 8727 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:16 5737 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-25 06:22:16 5744 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:15 2247 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:15 8233 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 06:22:15 8726 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 22:27:17 5344 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 22:27:13 6046 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 22:26:43 6029 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 22:26:41 8417 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 19:37:04 1930 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:04 2422 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:04 9438 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 19:37:04 9440 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:03 5944 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:01 1931 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:01 2422 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:01 9439 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 19:37:01 9446 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:37:00 5944 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:26 2013 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:26 2507 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:26 9523 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 19:23:26 9524 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:25 6028 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:24 2012 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:24 2507 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:24 9519 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 19:23:24 9525 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 19:23:23 6024 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 17:02:53 421 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 17:02:43 3955 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 17:02:23 3954 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 17:02:17 4153 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 16:53:12 402 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 16:53:12 404 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:11 2888 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:11 3382 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:10 397 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 16:53:10 404 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:10 6901 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:09 2890 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:09 3381 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:53:08 6901 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:59 394 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 16:52:59 396 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:58 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:58 3381 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:57 390 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 16:52:57 396 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:57 6898 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:56 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:56 3379 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:55 6899 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:40 396 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 16:52:40 398 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:39 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:39 3375 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:38 389 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 16:52:38 395 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:38 6897 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:37 2881 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:37 3377 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 16:52:36 6895 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:56 1214 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 14:30:56 1216 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:55 3694 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:55 4186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:54 1200 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 14:30:54 1207 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:54 7707 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:53 3693 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:53 4186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 14:30:52 7706 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:22 2224 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 11:34:22 2225 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:21 4714 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:21 5206 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:20 2220 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 11:34:20 2227 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:20 8726 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:19 4715 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:19 5207 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 11:34:18 8728 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 06:16:19 2144 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 06:16:13 440 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 06:15:53 448 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 06:15:43 5442 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 05:55:05 4189 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 05:55:05 4190 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:04 694 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:04 6683 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:04 7172 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:03 4184 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 05:55:03 4190 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:02 692 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:02 6679 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 05:55:02 7174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 05:10:35 4574 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 05:10:23 31 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 05:10:03 20 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 05:09:59 7907 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-23 16:16:14 1521 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:14 2016 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:14 9035 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 16:16:14 9037 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:13 5534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:12 1521 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:12 2014 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:12 9028 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 16:16:12 9034 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:16:11 5534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:02 1820 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:02 2314 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:02 9331 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 15:28:02 9333 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:01 5833 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:00 1820 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:00 2314 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:28:00 9329 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 15:28:00 9336 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 15:27:59 5833 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:43 1230 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 10:03:43 1232 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:42 3719 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:42 4212 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:41 1224 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 10:03:41 1231 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:41 7733 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:40 3718 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:40 4214 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 10:03:39 7730 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:09 536 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:09 1030 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:09 8050 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-22 14:44:09 8052 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:08 4550 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:05 535 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:05 1028 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:05 8042 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-22 14:44:05 8049 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 14:44:04 4549 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:22 1668 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:22 2160 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:22 9181 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-22 11:32:22 9182 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:21 5681 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:20 1666 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:20 2162 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:20 9172 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-22 11:32:20 9178 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 11:32:19 5680 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 09:37:38 1419 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - AS01
SHP Office DeltaV 2022-12-22 09:37:27 426 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-22 09:37:25 4925 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-22 09:37:25 4930 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - AS01
SHP Unit DeltaV 2022-12-22 09:15:12 1507 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-22 09:15:01 3042 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 09:14:41 3053 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 09:14:36 5046 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-22 04:21:36 2257 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-22 04:21:31 1373 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 04:21:11 1366 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 04:21:00 5957 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 20:18:19 4534 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 20:18:19 4535 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:18 1038 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:18 7024 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:18 7519 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:16 4534 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 20:18:16 4540 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:15 1038 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:15 7024 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 20:18:15 7518 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-21 18:39:36 8675 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 18:39:30 7355 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 18:39:10 7353 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 18:39:01 1846 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 17:30:43 5633 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 17:30:40 6920 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 17:30:10 6905 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 17:30:07 9394 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 15:40:14 6192 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 15:40:14 6193 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:13 2697 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:13 8680 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:13 9174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:11 6185 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 15:40:11 6192 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:10 2694 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:10 8680 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 15:40:10 9174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-21 15:16:19 749 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 15:16:10 6009 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 15:15:50 6008 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 15:15:43 4604 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 13:55:38 6795 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 13:55:38 6797 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:37 3288 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:37 9273 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:37 9766 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:34 6781 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 13:55:34 6787 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:33 3288 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:33 9273 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 13:55:33 9769 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:17 53 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:17 546 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:17 7560 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 11:43:17 7561 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:16 4068 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:13 52 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:13 548 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:13 7560 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 11:43:13 7567 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 11:43:12 4065 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 09:47:38 9777 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - AS01
SHP Office DeltaV 2022-12-21 09:47:37 8779 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 09:47:36 3277 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 09:47:36 3282 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - AS01
SHP Office DeltaV 2022-12-21 09:47:31 2970 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 09:47:29 5480 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 09:47:27 3279 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 09:47:27 8781 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 09:44:35 6530 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 09:44:35 9030 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 09:43:42 3325 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 09:43:42 8829 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Unit DeltaV 2022-12-21 08:47:05 7184 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 08:47:00 3493 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 08:46:40 3484 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 08:46:30 868 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 05:25:36 640 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 05:25:30 1703 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 05:25:10 1699 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 05:25:00 4186 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 01:06:47 6816 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 01:06:40 112 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 01:06:20 113 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 01:06:12 299 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-20 19:07:45 3421 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-20 19:07:45 3423 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:44 5908 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:44 6401 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:43 3415 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-20 19:07:43 3421 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:43 9921 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:42 5908 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:42 6403 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 19:07:41 9923 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:20 5580 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-20 13:04:20 5582 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:19 2085 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:19 8070 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:19 8564 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:16 5575 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-20 13:04:16 5582 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:15 2086 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:15 8071 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 13:04:15 8565 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 10:40:01 6296 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2022-12-20 10:40:00 2910 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 10:39:59 1154 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-20 10:39:59 3151 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-20 10:39:59 6254 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-20 10:39:59 6369 CHANGE USER AREA_A PROPLUS CNTRL01 MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-20 10:39:59 6419 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 10:39:59 8897 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 10:39:59 9388 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 10:39:58 9054 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-19 21:37:00 1040 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 21:37:00 1042 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:59 3522 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:59 4017 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:58 1031 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 21:36:58 1037 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:58 7534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:57 3522 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:57 4015 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 21:36:56 7534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:44 1449 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 20:26:44 1450 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:43 3939 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:43 4433 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:42 7951 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:41 1442 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 20:26:41 1448 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:40 3938 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:40 4434 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:26:39 7951 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:57 1551 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 20:07:57 1552 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:56 4041 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:56 4535 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:55 1551 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 20:07:55 1557 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:55 8058 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:54 4044 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:54 4538 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 20:07:53 8059 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:17 4111 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 12:57:17 4113 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:16 618 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:16 6604 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:16 7094 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:14 4111 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 12:57:14 4117 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:13 616 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:13 6605 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:57:13 7097 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:56 4165 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 12:48:56 4166 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:55 666 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:55 6654 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:55 7143 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:53 4158 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 12:48:53 4164 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:52 668 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:52 6653 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:48:52 7147 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:27 4234 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 12:39:27 4236 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:26 735 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:26 6723 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:26 7218 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:25 4229 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 12:39:25 4236 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:24 735 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:24 6723 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:39:24 7216 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:11:19 4939 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-19 12:11:18 7936 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-19 12:08:06 4395 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 12:08:06 4397 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:05 898 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:05 6884 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:05 7376 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:04 4393 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 12:08:04 4399 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:03 897 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:03 6884 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:08:03 7379 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 12:05:03 8190 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-19 12:05:02 3220 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2022-12-19 12:05:00 6031 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - AS01
SHP Office DeltaV 2022-12-19 12:04:55 9531 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - AS01
SHP Office DeltaV 2022-12-19 11:37:02 4594 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-19 11:37:02 4596 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:37:01 1094 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:37:01 7081 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:37:01 7574 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:36:59 4585 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-19 11:36:59 4591 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:36:58 1094 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:36:58 7080 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 11:36:58 7575 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-19 09:26:55 3330 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: NOT COMMUNICATING
SHP Office DeltaV 2022-12-19 09:26:54 5930 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-19 09:26:44 5243 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2022-12-19 09:26:44 5243 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM RECORD(S) LOST 4-INFO
SHP Office DeltaV 2022-12-19 09:26:44 5934 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-19 09:26:40 3030 STATUS SYSTEM AREA_A PROPLUS CNTRL01 NOT COMMUNICATING 4-INFO Previous node status was: OK