Event List (683286)

System Date/Time FracSec Event Event Subtype Category Area Node Unit Module Module Desc Attribute State Event Level Desc 1 Desc 2
SHP Office DeltaV 2023-01-02 13:42:10 6708 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-02 13:42:10 6709 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:09 3209 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:09 9197 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:09 9691 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:08 6718 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-02 13:42:08 6724 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:07 3210 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:07 9198 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 13:42:07 9691 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:10 444 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:10 7461 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-02 11:34:10 7462 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:09 3964 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:09 9949 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:07 443 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:07 7453 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-02 11:34:07 7459 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:06 3968 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-02 11:34:06 9951 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:19 1922 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-01 22:57:19 1923 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:18 4402 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:18 4898 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:17 1909 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-01 22:57:17 1916 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:17 8414 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:16 4402 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:16 4895 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 22:57:15 8414 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:36 5202 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-01 13:18:36 5204 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:35 1706 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:35 7693 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:35 8186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:34 5202 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-01 13:18:34 5208 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:33 1710 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:33 7696 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 13:18:33 8186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:46 5390 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-01 12:45:46 5392 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:45 1895 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:45 7880 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:45 8374 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:44 5388 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-01 12:45:44 5394 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:43 1896 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:43 7883 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:45:43 8374 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:50 5488 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2023-01-01 12:28:50 5490 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:49 2000 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:49 7981 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:49 8474 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:45 5487 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2023-01-01 12:28:45 5494 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:44 1995 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:44 7983 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2023-01-01 12:28:44 8475 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2023-01-01 03:58:47 3364 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2023-01-01 03:58:40 564 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2023-01-01 03:58:20 560 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2023-01-01 03:58:11 6637 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-31 14:42:09 3047 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-31 14:42:09 3048 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:08 5532 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:08 6033 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:07 9546 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:06 3047 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-31 14:42:06 3054 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:05 5534 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:05 6033 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 14:42:04 9546 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:52 3733 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-31 12:42:52 3736 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:51 240 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:51 6222 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:51 6718 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:49 3731 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-31 12:42:49 3738 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:48 242 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:48 6225 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-31 12:42:48 6720 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-31 07:03:48 1963 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-31 07:03:39 5260 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-31 07:03:19 5267 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-31 07:03:12 5256 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-31 01:07:04 8676 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-31 01:06:59 2941 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-31 01:06:39 2944 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-31 01:06:29 1941 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-30 16:08:02 6739 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-30 16:07:58 9421 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-30 16:07:28 9408 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-30 16:07:26 9896 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-30 15:02:26 1486 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-30 15:02:26 1488 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:25 3977 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:25 4469 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:24 1478 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-30 15:02:24 1485 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:24 7990 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:23 3973 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:23 4469 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-30 15:02:22 7987 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-30 11:31:38 7590 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C09, CH08
SHP Unit DeltaV 2022-12-30 11:31:36 7595 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C06, CH04
SHP Unit DeltaV 2022-12-30 11:31:05 3920 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 completed successfully
SHP Unit DeltaV 2022-12-30 11:30:51 7930 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 completed successfully
SHP Unit DeltaV 2022-12-30 11:30:49 7210 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 started
SHP Unit DeltaV 2022-12-30 11:30:36 7602 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C06, CH04
SHP Unit DeltaV 2022-12-30 11:30:35 5915 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-30 11:30:35 8460 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTR01 started
SHP Unit DeltaV 2022-12-30 11:30:34 3970 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator Start of Download - 0
SHP Unit DeltaV 2022-12-30 11:30:34 4810 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator End of download. - 0
SHP Unit DeltaV 2022-12-30 11:30:34 8364 DOWNLOAD USER AREA_A CNTR01 CNTR01 UPDATE Administrator Start of Download - 0
SHP Unit DeltaV 2022-12-30 11:30:34 9072 DOWNLOAD USER AREA_A CNTR01 IO1/C06 UPDATE Administrator Partial Download of I/O Card
SHP Unit DeltaV 2022-12-30 11:30:34 9715 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-30 11:30:34 9931 DOWNLOAD USER AREA_A CNTR01 CNTR01 UPDATE Administrator End of download. - 0
SHP Unit DeltaV 2022-12-30 11:25:02 7571 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller ADVISE_ALM ACT/ACK 07-ADVISORY ADVISE [MULT]IO: Channel Error - AI Card, C09, CH08
SHP Unit DeltaV 2022-12-30 11:21:16 9710 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2022-12-29 18:29:04 1230 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:04 1725 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:04 8738 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 18:29:04 8740 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:03 5244 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:00 1232 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:00 1728 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:29:00 8736 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 18:29:00 8743 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 18:28:59 5245 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:04 1110 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 11:47:04 1112 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:03 3599 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:03 4094 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:02 1114 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 11:47:02 1122 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:02 7612 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:01 3599 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:01 4092 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:47:00 7612 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:58 1283 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-29 11:18:58 1284 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:57 3774 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:57 4266 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:56 7788 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:54 1279 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-29 11:18:54 1286 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:53 3772 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:53 4265 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-29 11:18:52 7785 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-29 00:32:19 1064 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-29 00:32:07 4151 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-29 00:31:47 4149 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-29 00:31:43 4639 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-28 21:27:08 6217 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 21:27:08 6219 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:07 2718 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:07 8706 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:07 9195 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:06 6210 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 21:27:06 6216 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:05 2721 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:05 8703 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 21:27:05 9199 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:15 852 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:15 1347 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:15 8359 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 15:27:15 8361 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:14 4864 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:13 851 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:13 1345 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:13 8357 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 15:27:13 8363 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:27:12 4864 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:33 948 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:33 1442 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:33 8455 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-28 15:07:33 8457 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:32 4960 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:29 950 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:29 1440 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:29 8453 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-28 15:07:29 8459 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-28 15:07:28 4962 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-28 14:51:15 3577 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-28 14:51:07 358 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 14:50:47 365 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 14:50:39 7261 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-28 00:27:47 4747 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-28 00:27:36 4792 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 00:27:16 4803 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-28 00:27:11 8296 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-27 13:53:15 6585 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-27 13:53:06 729 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 13:52:46 742 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 13:52:40 135 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-27 01:09:36 2562 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-27 01:09:25 6133 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 01:09:05 6139 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-27 01:09:00 6242 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-26 19:03:57 3858 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-26 19:03:57 3860 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:56 363 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:56 6352 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:56 6844 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:55 3856 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-26 19:03:55 3863 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:54 368 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:54 6352 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 19:03:54 6844 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:47 5258 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-26 14:46:47 5260 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:46 1764 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:46 7751 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:46 8245 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:44 5270 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-26 14:46:44 5277 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:43 1762 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:43 7749 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-26 14:46:43 8244 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:18 3140 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-25 15:03:18 3141 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:17 5632 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:17 6126 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:16 3138 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-25 15:03:16 3144 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:16 9645 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:15 5635 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:15 6125 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 15:03:14 9645 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:18 5744 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-25 07:22:18 5746 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:17 2248 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:17 8233 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:17 8727 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:16 5737 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-25 07:22:16 5744 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:15 2247 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:15 8233 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-25 07:22:15 8726 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 23:27:17 5344 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 23:27:13 6046 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 23:26:43 6029 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 23:26:41 8417 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 20:37:04 1930 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:04 2422 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:04 9438 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 20:37:04 9440 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:03 5944 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:01 1931 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:01 2422 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:01 9439 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 20:37:01 9446 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:37:00 5944 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:26 2013 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:26 2507 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:26 9523 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 20:23:26 9524 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:25 6028 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:24 2012 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:24 2507 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:24 9519 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 20:23:24 9525 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 20:23:23 6024 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 18:02:53 421 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 18:02:43 3955 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 18:02:23 3954 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 18:02:17 4153 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 17:53:12 402 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 17:53:12 404 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:11 2888 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:11 3382 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:10 397 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 17:53:10 404 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:10 6901 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:09 2890 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:09 3381 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:53:08 6901 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:59 394 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 17:52:59 396 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:58 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:58 3381 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:57 390 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 17:52:57 396 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:57 6898 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:56 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:56 3379 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:55 6899 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:40 396 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 17:52:40 398 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:39 2885 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:39 3375 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:38 389 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 17:52:38 395 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:38 6897 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:37 2881 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:37 3377 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 17:52:36 6895 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:56 1214 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 15:30:56 1216 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:55 3694 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:55 4186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:54 1200 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 15:30:54 1207 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:54 7707 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:53 3693 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:53 4186 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 15:30:52 7706 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:22 2224 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 12:34:22 2225 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:21 4714 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:21 5206 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:20 2220 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 12:34:20 2227 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:20 8726 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:19 4715 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:19 5207 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 12:34:18 8728 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 07:16:19 2144 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 07:16:13 440 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 07:15:53 448 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 07:15:43 5442 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-24 06:55:05 4189 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-24 06:55:05 4190 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:04 694 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:04 6683 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:04 7172 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:03 4184 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-24 06:55:03 4190 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:02 692 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:02 6679 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-24 06:55:02 7174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-24 06:10:35 4574 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-24 06:10:23 31 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 06:10:03 20 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-24 06:09:59 7907 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-23 17:16:14 1521 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:14 2016 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:14 9035 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 17:16:14 9037 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:13 5534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:12 1521 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:12 2014 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:12 9028 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 17:16:12 9034 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 17:16:11 5534 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:02 1820 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:02 2314 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:02 9331 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 16:28:02 9333 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:01 5833 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:00 1820 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:00 2314 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:28:00 9329 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 16:28:00 9336 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 16:27:59 5833 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:43 1230 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-23 11:03:43 1232 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:42 3719 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:42 4212 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:41 1224 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-23 11:03:41 1231 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:41 7733 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:40 3718 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:40 4214 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-23 11:03:39 7730 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:09 536 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:09 1030 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:09 8050 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-22 15:44:09 8052 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:08 4550 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:05 535 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:05 1028 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:05 8042 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-22 15:44:05 8049 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 15:44:04 4549 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:22 1668 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:22 2160 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:22 9181 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-22 12:32:22 9182 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:21 5681 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:20 1666 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:20 2162 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:20 9172 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-22 12:32:20 9178 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 12:32:19 5680 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-22 10:37:38 1419 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - AS01
SHP Office DeltaV 2022-12-22 10:37:27 426 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-22 10:37:25 4925 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-22 10:37:25 4930 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - AS01
SHP Unit DeltaV 2022-12-22 10:15:12 1507 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-22 10:15:01 3042 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 10:14:41 3053 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 10:14:36 5046 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-22 05:21:36 2257 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-22 05:21:31 1373 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 05:21:11 1366 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-22 05:21:00 5957 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 21:18:19 4534 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 21:18:19 4535 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:18 1038 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:18 7024 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:18 7519 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:16 4534 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 21:18:16 4540 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:15 1038 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:15 7024 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 21:18:15 7518 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-21 19:39:36 8675 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 19:39:30 7355 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 19:39:10 7353 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 19:39:01 1846 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 18:30:43 5633 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 18:30:40 6920 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 18:30:10 6905 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 18:30:07 9394 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 16:40:14 6192 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 16:40:14 6193 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:13 2697 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:13 8680 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:13 9174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:11 6185 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 16:40:11 6192 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:10 2694 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:10 8680 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 16:40:10 9174 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2022-12-21 16:16:19 749 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 16:16:10 6009 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 16:15:50 6008 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 16:15:43 4604 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-21 14:55:38 6795 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 14:55:38 6797 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:37 3288 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:37 9273 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:37 9766 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:34 6781 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 14:55:34 6787 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:33 3288 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:33 9273 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 14:55:33 9769 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:17 53 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:17 546 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:17 7560 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-21 12:43:17 7561 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:16 4068 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:13 52 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:13 548 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:13 7560 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-21 12:43:13 7567 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 12:43:12 4065 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-21 10:47:38 9777 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - AS01
SHP Office DeltaV 2022-12-21 10:47:37 8779 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 10:47:36 3277 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 10:47:36 3282 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - AS01
SHP Office DeltaV 2022-12-21 10:47:31 2970 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 10:47:29 5480 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 10:47:27 3279 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 10:47:27 8781 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 10:44:35 6530 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 10:44:35 9030 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2022-12-21 10:43:42 3325 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2022-12-21 10:43:42 8829 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Unit DeltaV 2022-12-21 09:47:05 7184 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 09:47:00 3493 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 09:46:40 3484 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 09:46:30 868 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 06:25:36 640 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 06:25:30 1703 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 06:25:10 1699 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 06:25:00 4186 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Unit DeltaV 2022-12-21 02:06:47 6816 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Available
SHP Unit DeltaV 2022-12-21 02:06:40 112 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM INACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 02:06:20 113 ALARM HARDWARE AREA_A CNTR01 CNTR01 Rig Controller MAINT_ALM ACT/UNACK 11-WARNING MAINT Redundancy: Not Communicating - Standby
SHP Unit DeltaV 2022-12-21 02:06:12 299 EVENT SYSTEM AREA_A CNTR01 REDU 00-80-74-01-83-6E Standby is now Unavailable
SHP Office DeltaV 2022-12-20 20:07:45 3421 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-20 20:07:45 3423 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:44 5908 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:44 6401 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:43 3415 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-20 20:07:43 3421 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:43 9921 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:42 5908 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:42 6403 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 20:07:41 9923 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:20 5580 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2022-12-20 14:04:20 5582 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:19 2085 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:19 8070 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:19 8564 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:16 5575 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2022-12-20 14:04:16 5582 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:15 2086 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:15 8071 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 14:04:15 8565 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 11:40:01 6296 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2022-12-20 11:40:00 2910 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2022-12-20 11:39:59 1154 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2022-12-20 11:39:59 3151 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0