System Date/Time FracSec Event Event Subtype Category Area Node Unit Module Module Desc Attribute State Event Level Desc 1 Desc 2
SHP Unit DeltaV 2016-05-14 13:05:39 600 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 13:05:15 5090 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 13:03:16 2575 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 13:03:16 2577 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 13:03:15 2578 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 13:02:50 5820 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 13:02:40 2580 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 13:02:40 2581 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 13:02:39 2579 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 13:01:31 6089 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:57:46 5570 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:57:38 5820 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:56:57 5571 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:56:16 2574 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:56:16 2576 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 12:56:15 2578 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:55:24 2577 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:55:24 2578 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 12:55:23 2577 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:54:50 1010 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:52:35 2571 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:52:35 2572 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 12:52:34 2574 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:50:33 6566 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:50:06 6078 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:49:38 1010 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:47:28 5072 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:46:56 2564 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:46:56 2565 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 12:46:55 2564 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:46:49 6200 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:43:22 6551 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:43:15 5062 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:41:37 6200 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:41:35 5063 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:41:26 6553 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:40:13 2551 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:40:13 2552 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 12:40:12 2553 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:39:39 6062 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:39:23 6061 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:38:49 1390 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:38:42 5054 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:38:23 5543 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:37:56 6549 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:37:11 5545 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:36:38 2551 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:36:38 2552 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 12:36:37 2552 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:35:56 5545 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:34:37 6050 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:34:08 5539 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:34:03 6543 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:33:37 1390 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:32:38 6539 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:31:44 2541 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:31:44 2543 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 12:31:43 2544 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:30:59 6055 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:30:55 5542 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:30:48 6590 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:30:36 6544 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:30:13 5539 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:29:49 6540 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:26:13 2535 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:26:13 2536 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 12:26:12 2536 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:25:36 6580 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:24:30 5038 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:22:48 1780 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:22:20 6525 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:22:09 2525 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:22:09 2527 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 12:22:08 2528 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:21:53 6037 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:21:34 6527 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:18:06 5519 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:17:48 6034 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:17:36 1780 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:16:46 5518 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:16:16 6035 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:15:06 5518 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:14:47 2524 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 12:14:47 2525 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 12:14:47 6980 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:14:46 2523 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:14:44 5519 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:14:33 6034 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:13:53 5030 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:13:36 6518 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:13:01 6519 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:12:48 5027 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:12:27 6029 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:11:38 6030 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:10:05 6025 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:09:48 6028 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:09:45 6516 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:09:35 6980 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:09:18 6516 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:08:34 6024 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:08:00 5024 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:07:31 6024 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:06:47 2170 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:05:51 6510 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:03:35 5500 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:01:46 6501 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:01:35 2170 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 12:01:06 5007 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 12:00:45 6010 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:59:42 6011 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:59:12 5494 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:58:46 7370 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:58:14 5001 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:57:04 6492 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:56:42 5494 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:56:22 5497 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:56:03 6495 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:54:48 5491 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:54:31 6494 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:53:34 7360 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:52:58 5000 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:52:40 5487 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:51:25 6001 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:50:46 2560 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:50:24 5999 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:49:56 4997 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:49:06 6487 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:46:14 5482 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:45:59 6481 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:45:34 2550 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:45:19 4992 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:44:57 2478 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:44:57 2479 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:44:56 2481 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:44:26 5477 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:43:45 6474 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:42:45 7750 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:42:09 4980 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:41:50 5471 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:40:20 2480 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:40:20 2481 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:40:19 2481 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:39:12 5984 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:38:31 5464 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:37:33 7740 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:37:10 5983 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:36:56 6471 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:36:32 2471 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:36:32 2473 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:36:31 2473 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:36:13 2474 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:36:13 2475 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:36:12 2474 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:35:50 4982 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:35:34 5984 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:35:19 5471 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:34:46 5986 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:34:45 2940 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:34:35 985 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:34:31 988 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:34:26 5472 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:34:19 2473 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:34:19 2475 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:34:18 2476 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:32:58 2472 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:32:58 2474 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:32:57 2473 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:31:53 5464 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:31:18 6467 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:31:14 4976 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:30:49 980 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:30:45 984 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:30:30 2464 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:30:30 2466 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:30:29 2468 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:30:13 2466 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:30:13 2467 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:30:12 2466 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:29:33 2940 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:28:55 5974 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:28:07 979 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:28:04 977 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 11:27:57 4971 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:27:22 5974 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:27:01 6458 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:26:44 8140 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:26:43 4969 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:26:15 6455 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:25:56 5452 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:25:36 4965 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:24:16 2454 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:24:16 2455 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:24:15 2456 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:23:46 5969 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:23:14 6454 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:22:38 2453 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:22:38 2454 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:22:37 2454 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:21:39 540 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:21:37 6449 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:21:20 4958 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:18:50 5740 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:18:33 4960 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:16:19 5964 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:15:30 4960 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:14:55 6450 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:14:29 5961 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:14:10 6449 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:13:38 5730 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:13:18 5957 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:12:54 4953 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:12:23 5953 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:11:55 4949 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:10:50 930 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:10:40 2441 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:10:40 2443 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:10:39 2444 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:10:39 4950 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:09:39 2440 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:09:39 2441 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:09:38 2441 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:09:06 5439 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:08:00 4945 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:06:11 5433 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:05:38 920 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:05:16 4940 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:04:50 5947 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:04:22 2430 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:04:22 2432 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 11:04:21 2434 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:03:54 4938 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:03:35 4937 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:03:17 2429 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 11:03:17 2430 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 11:03:16 2429 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:02:49 5936 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:02:49 6110 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 11:02:30 5422 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:02:11 6425 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:01:21 5936 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:00:36 5419 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:00:28 6420 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 11:00:13 4927 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:59:28 5414 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:59:10 5415 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:57:37 6110 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:57:07 5408 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:55:37 5930 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:55:11 4932 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:54:56 5417 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:54:49 1310 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:53:36 5932 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:53:33 5417 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:53:12 5415 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:52:59 4923 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:52:41 4922 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:51:14 5412 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:50:09 6410 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:49:37 1320 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:49:19 4922 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:48:00 5925 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:47:09 5408 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:46:48 6510 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:46:32 5920 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:46:25 6407 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:46:13 4917 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:46:08 5922 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:45:22 5921 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:45:10 2405 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:45:10 2407 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:45:09 2408 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:43:50 2409 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:43:50 2410 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:43:49 2410 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:41:36 6510 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:40:58 6395 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:40:08 2396 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:40:08 2398 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:40:07 2400 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:38:48 1710 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:38:36 6394 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:37:58 5910 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:36:26 2401 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:36:26 2402 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:36:25 2402 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:36:05 5914 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:35:44 6400 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:33:50 5394 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:33:36 1700 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:33:35 6396 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:33:27 5393 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:33:03 2394 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:33:03 2396 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:33:02 2396 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:32:08 6394 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:30:47 6900 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:28:53 2390 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:28:53 2391 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:28:52 2390 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:27:55 6388 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:27:10 4896 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:26:51 4894 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:26:43 2384 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:26:43 2386 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:26:42 2387 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:26:25 2387 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:26:25 2389 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:26:24 2388 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:26:18 6385 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:25:59 6385 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:25:40 4894 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:25:35 6890 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:24:26 4891 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:24:23 6382 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:24:08 5380 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:23:49 5379 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:23:06 6381 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:22:59 2380 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:22:59 2382 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:22:58 2384 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:22:47 2080 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:22:30 4889 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:22:11 5375 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:21:20 5375 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:20:49 6376 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:19:31 6371 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:17:35 2090 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:16:33 2376 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:16:33 2377 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:16:32 2376 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:16:31 4882 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:16:30 6372 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:15:56 6373 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:15:29 5884 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:14:46 7290 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:14:22 4879 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:13:59 6372 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:12:27 6367 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:11:50 4878 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:11:14 5879 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:11:11 6367 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:10:32 4876 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:09:34 7280 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:09:28 5877 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:08:49 4873 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:08:41 2363 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:08:41 2365 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:08:40 2366 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:06:46 2480 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:06:25 4870 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:06:06 2362 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:06:06 2363 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:06:05 2362 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:05:41 5356 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:05:23 6358 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:04:39 5356 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:04:36 2357 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:04:36 2359 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 10:04:35 2359 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:04:15 5868 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:02:14 5351 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:01:35 5866 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 10:01:34 2480 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 10:00:29 2353 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 10:00:29 2355 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 10:00:28 2354 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:59:58 5350 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:58:45 7680 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:57:45 4857 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:57:14 6349 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:56:56 5860 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:56:40 2348 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:56:40 2349 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:56:39 2352 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:56:12 5345 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:53:33 7670 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:53:27 5345 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:52:37 5858 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:52:19 6345 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:50:45 2870 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:48:37 4846 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:48:14 2337 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:48:14 2338 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:48:13 2338 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:47:53 4844 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:47:53 5846 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:47:34 6333 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:47:15 6331 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:46:54 5841 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:46:34 5325 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:46:11 5329 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:45:33 2860 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:45:15 2331 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:45:15 2333 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:45:14 2334 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:44:52 2335 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:44:52 2336 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:44:51 2335 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:44:15 4838 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:43:09 4837 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:43:05 5325 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:42:44 8060 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:42:36 2328 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:42:36 2330 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:42:35 2333 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:41:58 2331 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:41:58 2333 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:41:57 2331 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:41:39 4836 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:41:39 5839 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:41:08 5324 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:40:57 6326 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:40:42 6326 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:40:37 4836 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:39:40 5837 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:39:25 5322 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:38:41 5321 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:38:37 6325 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:38:00 4833 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:37:32 8050 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:36:41 5834 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:36:06 4828 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:35:46 5319 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:35:37 2320 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:35:37 2322 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:35:36 2323 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:34:56 6319 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:34:44 3260 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:34:30 5317 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:34:23 2322 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:34:23 2323 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:34:22 2321 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:33:29 6315 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:31:28 5316 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:29:52 5312 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:29:32 3250 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:27:30 4818 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:26:47 4816 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:26:46 6306 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:26:43 8450 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:26:27 5820 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:24:04 5308 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:24:04 5822 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:23:49 5306 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:22:59 5303 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:21:54 5301 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:21:38 4812 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:21:31 8450 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:21:26 6304 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:19:28 6297 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:19:24 2296 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:19:24 2298 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:19:23 2298 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:18:58 5805 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:18:43 3640 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:17:06 5290 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:16:51 5290 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:15:47 6299 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:15:29 2301 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:15:29 2303 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:15:28 2302 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:15:17 4809 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:14:59 810 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 09:14:55 813 ALARM INSTRUMENT BOILER CNTR01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Unit DeltaV 2016-05-14 09:14:40 5294 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:13:31 3630 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:12:02 2294 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:12:02 2295 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 09:12:01 2296 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:11:26 2295 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 09:11:26 2296 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Unit DeltaV 2016-05-14 09:11:25 2295 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:10:51 6290 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:10:50 5804 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:10:42 8840 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:09:53 6286 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:09:17 4790 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:08:49 5279 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:06:10 6284 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:05:55 5797 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:05:30 8830 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:04:00 4789 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:04:00 6280 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:02:59 5789 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:02:42 4030 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 09:01:59 6275 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:01:48 4782 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:00:31 5270 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 09:00:16 6274 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:59:43 5786 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:59:14 5270 ALARM INSTRUMENT BOILER CNTR01 TI101 PR Cabinet Temperature DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:58:50 5785 ALARM INSTRUMENT BOILER CNTR01 PR9116_2 POT 2 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:57:59 4780 ALARM INSTRUMENT BOILER CNTR01 PR9116_1 POT 1 DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:57:30 4020 EVENT SYSTEM AREA_A AS01 ACN COMM ACTIVE 4-INFO Device Connection Failure - WS01
SHP Unit DeltaV 2016-05-14 08:57:16 6271 ALARM INSTRUMENT BOILER CNTR01 PR9202_1 HiHi Switch DEV_OFFLINE_ALM INACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:57:13 2271 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 I/O Input Failure
SHP Unit DeltaV 2016-05-14 08:57:13 2273 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO PR_CAB_TEMP/AI1 Module Failure Active
SHP Unit DeltaV 2016-05-14 08:57:12 2275 ALARM INSTRUMENT BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature DEV_OFFLINE_ALM ACT/UNACK 15-CRITICAL COMM Communication Error
SHP Unit DeltaV 2016-05-14 08:56:42 2277 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Unit DeltaV 2016-05-14 08:56:42 2279 EVENT PROCESS BOILER CNTR01 PR_CAB_TEMP PR9106 Cabinet Temperature ACTIVE 4-INFO Error Cleared Module Failure Active