Event List (669696)

System Date/Time FracSec Event Event Subtype Category Area Node Unit Module Module Desc Attribute State Event Level Desc 1 Desc 2
SHP Office DeltaV 2018-10-04 11:52:07 5200 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-04 11:52:07 8927 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-04 11:52:07 9083 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-04 11:51:53 8920 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-04 11:51:49 8920 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-04 11:51:38 7861 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-04 11:50:31 2094 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:28 2626 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-04 11:50:11 365 ALARM INSTRUMENT BOILER CNTRL01 PIC101 Steam Pressure PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:50:10 2469 CHANGE USER BOILER PROPLUS ANALOG1 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:10 2576 CHANGE USER BOILER PROPLUS PIC101 Steam Pressure PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:10 2600 CHANGE USER BOILER PROPLUS LIC103 Hotwell Level PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:10 2624 CHANGE USER BOILER PROPLUS XV110 Well Head Valve FAIL_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:10 2652 CHANGE USER BOILER PROPLUS LIC103 Hotwell Level LO_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-04 11:50:10 6860 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level LO_ALM INACT/ACK 11-WARNING LOW Low Alarm Value 320.425 Limit 300
SHP Office DeltaV 2018-10-04 11:50:10 6863 ALARM INSTRUMENT BOILER CNTRL01 LIC103 Hotwell Level PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:50:10 7375 ALARM INSTRUMENT BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 PVBAD_ALM ACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:50:10 9862 ALARM PROCESS BOILER CNTRL01 XV110 Well Head Valve FAIL_ALM INACT/ACK 11-WARNING FAILED Clear
SHP Office DeltaV 2018-10-04 11:49:57 90 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-04 11:49:55 7770 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 completed successfully
SHP Office DeltaV 2018-10-04 11:49:44 4510 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 completed successfully
SHP Office DeltaV 2018-10-04 11:49:41 1910 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 started
SHP Office DeltaV 2018-10-04 11:49:41 9860 STATUS SYSTEM AREA_A PROPLUS CNTRL01 BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-04 11:49:38 2434 EVENT SYSTEM AREA_A CNTRL01 REDU 00-80-74-01-83-3C Standby is now Available
SHP Office DeltaV 2018-10-04 11:49:37 9300 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 completed successfully
SHP Office DeltaV 2018-10-04 11:49:33 342 EVENT PROCESS BOILER CNTRL01 PIC101 Steam Pressure ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:33 344 EVENT PROCESS BOILER CNTRL01 PIC101 Steam Pressure ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Office DeltaV 2018-10-04 11:49:33 345 ALARM INSTRUMENT BOILER CNTRL01 PIC101 Steam Pressure PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:33 6836 EVENT PROCESS BOILER CNTRL01 LIC103 Hotwell Level ACTIVE 4-INFO LIC103/PID1/PV_SCALE Inputs Transfer Failure
SHP Office DeltaV 2018-10-04 11:49:32 348 EVENT PROCESS BOILER CNTRL01 PIC101 Steam Pressure ACTIVE 4-INFO PIC101/PID1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:32 350 EVENT PROCESS BOILER CNTRL01 PIC101 Steam Pressure ACTIVE 4-INFO PIC101/PID1 Module Failure Active
SHP Office DeltaV 2018-10-04 11:49:32 352 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure HI_HI_ALM DISABLED 15-CRITICAL HIHI High High Alarm Value 0 Limit 8
SHP Office DeltaV 2018-10-04 11:49:32 354 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure HI_ALM DISABLED 11-WARNING HIGH High Alarm Value 0 Limit 4
SHP Office DeltaV 2018-10-04 11:49:32 355 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure LO_ALM DISABLED 11-WARNING LOW Low Alarm Value 0 Limit 400
SHP Office DeltaV 2018-10-04 11:49:32 357 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure LO_LO_ALM DISABLED 15-CRITICAL LOLO Low Low Alarm Value 0 Limit 250
SHP Office DeltaV 2018-10-04 11:49:32 358 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure DV_HI_ALM DISABLED 07-ADVISORY DEV Deviation Alarm Actual 0 Target 0
SHP Office DeltaV 2018-10-04 11:49:32 359 ALARM PROCESS BOILER CNTRL01 PIC101 Steam Pressure DV_LO_ALM DISABLED 07-ADVISORY DEV Deviation Alarm Actual 0 Target 0
SHP Office DeltaV 2018-10-04 11:49:32 361 ALARM INSTRUMENT BOILER CNTRL01 PIC101 Steam Pressure PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:32 4383 EVENT PROCESS BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:32 6840 EVENT PROCESS BOILER CNTRL01 LIC103 Hotwell Level ACTIVE 4-INFO Error Cleared Module Failure Active
SHP Office DeltaV 2018-10-04 11:49:32 6841 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level LO_ALM INACT/UNACK 11-WARNING LOW Low Alarm Value 320.449 Limit 300
SHP Office DeltaV 2018-10-04 11:49:32 6844 ALARM INSTRUMENT BOILER CNTRL01 LIC103 Hotwell Level PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:32 7849 EVENT PROCESS BOILER CNTRL01 TIC102 Boiler temperature ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:32 9844 ALARM PROCESS BOILER CNTRL01 XV110 Well Head Valve FAIL_ALM INACT/UNACK 11-WARNING FAILED Clear
SHP Office DeltaV 2018-10-04 11:49:31 1827 DOWNLOAD USER AREA_A CNTRL01 CNTRL01 UPDATE Administrator End of download. - 0
SHP Office DeltaV 2018-10-04 11:49:31 1904 EVENT SYSTEM AREA_A CNTRL01 REDU 00-80-74-01-83-3C Standby is now Unavailable
SHP Office DeltaV 2018-10-04 11:49:31 1910 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 started
SHP Office DeltaV 2018-10-04 11:49:31 2338 ALARM PROCESS BOILER CNTRL01 F106 Combustion Air Fan FAIL_ALM INACT/ACK 11-WARNING FAILED Clear
SHP Office DeltaV 2018-10-04 11:49:31 2380 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 started
SHP Office DeltaV 2018-10-04 11:49:31 4385 EVENT PROCESS BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 ACTIVE 4-INFO PC_AO1/PID1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:31 4399 ALARM INSTRUMENT BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 4835 ALARM PROCESS BOILER CNTRL01 LS107 Boiler HIHI Level DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-04 11:49:31 4837 ALARM INSTRUMENT BOILER CNTRL01 LS107 Boiler HIHI Level PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 5361 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 5849 ALARM PROCESS BOILER CNTRL01 F105 Boiler Feed Pump FAIL_ALM INACT/ACK 11-WARNING FAILED Clear
SHP Office DeltaV 2018-10-04 11:49:31 6843 EVENT PROCESS BOILER CNTRL01 LIC103 Hotwell Level ACTIVE 4-INFO LIC103/PID1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:31 6845 EVENT PROCESS BOILER CNTRL01 LIC103 Hotwell Level ACTIVE 4-INFO LIC103/PID1 Module Failure Active
SHP Office DeltaV 2018-10-04 11:49:31 6849 EVENT PROCESS BOILER CNTRL01 LIC103 Hotwell Level ACTIVE 4-INFO LIC103/DI1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:31 6851 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level HI_HI_ALM INACT/ACK 15-CRITICAL HIHI High High Alarm Value 0 Limit 785
SHP Office DeltaV 2018-10-04 11:49:31 6853 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level HI_ALM DISABLED 11-WARNING HIGH High Alarm Value 0 Limit 750
SHP Office DeltaV 2018-10-04 11:49:31 6854 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level LO_ALM ACT/UNACK 11-WARNING LOW Low Alarm Value 0 Limit 300
SHP Office DeltaV 2018-10-04 11:49:31 6856 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level LO_LO_ALM DISABLED 15-CRITICAL LOLO Low Low Alarm Value 0 Limit 250
SHP Office DeltaV 2018-10-04 11:49:31 6858 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level DV_HI_ALM INACT/ACK 07-ADVISORY DEV Deviation Alarm Actual 0 Target 483
SHP Office DeltaV 2018-10-04 11:49:31 6859 ALARM PROCESS BOILER CNTRL01 LIC103 Hotwell Level DV_LO_ALM DISABLED 07-ADVISORY DEV Deviation Alarm Actual 0 Target 483
SHP Office DeltaV 2018-10-04 11:49:31 6861 ALARM INSTRUMENT BOILER CNTRL01 LIC103 Hotwell Level PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 7351 EVENT PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG1/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:31 7358 ALARM PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 HI_HI_ALM DISABLED 15-CRITICAL HIHI High High Alarm Value 0 Limit 95
SHP Office DeltaV 2018-10-04 11:49:31 7360 ALARM PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 HI_ALM DISABLED 11-WARNING HIGH High Alarm Value 0 Limit 90
SHP Office DeltaV 2018-10-04 11:49:31 7361 ALARM PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 LO_ALM DISABLED 11-WARNING LOW Low Alarm Value 0 Limit 10
SHP Office DeltaV 2018-10-04 11:49:31 7363 ALARM PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 LO_LO_ALM DISABLED 15-CRITICAL LOLO Low Low Alarm Value 0 Limit 5
SHP Office DeltaV 2018-10-04 11:49:31 7364 ALARM INSTRUMENT BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 7861 EVENT PROCESS BOILER CNTRL01 TIC102 Boiler temperature ACTIVE 4-INFO TIC102/PID1 I/O Input Failure
SHP Office DeltaV 2018-10-04 11:49:31 7866 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature HI_HI_ALM INACT/ACK 15-CRITICAL HIHI High High Alarm Value 0 Limit 80
SHP Office DeltaV 2018-10-04 11:49:31 7868 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature HI_ALM INACT/ACK 11-WARNING HIGH High Alarm Value 0 Limit 60
SHP Office DeltaV 2018-10-04 11:49:31 7869 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature LO_ALM DISABLED 11-WARNING LOW Low Alarm Value 0 Limit 400
SHP Office DeltaV 2018-10-04 11:49:31 7871 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature LO_LO_ALM DISABLED 15-CRITICAL LOLO Low Low Alarm Value 0 Limit 250
SHP Office DeltaV 2018-10-04 11:49:31 7873 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature DV_HI_ALM DISABLED 07-ADVISORY DEV Deviation Alarm Actual 0 Target 20
SHP Office DeltaV 2018-10-04 11:49:31 7874 ALARM PROCESS BOILER CNTRL01 TIC102 Boiler temperature DV_LO_ALM DISABLED 07-ADVISORY DEV Deviation Alarm Actual 0 Target 20
SHP Office DeltaV 2018-10-04 11:49:31 7876 ALARM INSTRUMENT BOILER CNTRL01 TIC102 Boiler temperature PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 8354 ALARM PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 HI_HI_ALM DISABLED 15-CRITICAL HIHI High High Alarm Value 0 Limit 95
SHP Office DeltaV 2018-10-04 11:49:31 8357 ALARM PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 HI_ALM DISABLED 11-WARNING HIGH High Alarm Value 0 Limit 90
SHP Office DeltaV 2018-10-04 11:49:31 8358 ALARM PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 LO_ALM DISABLED 11-WARNING LOW Low Alarm Value 0 Limit 10
SHP Office DeltaV 2018-10-04 11:49:31 8359 ALARM PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 LO_LO_ALM DISABLED 15-CRITICAL LOLO Low Low Alarm Value 0 Limit 5
SHP Office DeltaV 2018-10-04 11:49:31 8361 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 8840 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-04 11:49:31 8843 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 9377 ALARM PROCESS BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-04 11:49:31 9379 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-04 11:49:31 9851 ALARM PROCESS BOILER CNTRL01 XV110 Well Head Valve FAIL_ALM ACT/UNACK 11-WARNING FAILED CLOSED confirm lost
SHP Office DeltaV 2018-10-04 11:49:30 1965 DOWNLOAD USER BOILER CNTRL01 LIC103 Hotwell Level UPDATE Administrator Attribute Override Failure: PID1/OUT_HI_LIM TO 1000
SHP Office DeltaV 2018-10-04 11:49:28 1146 ALARM DEVICE AREA_A CNTRL01 CNTRL01C01CH01 COMM_ALM INACT/ACK 11-WARNING OK Communications failure
SHP Office DeltaV 2018-10-04 11:49:28 1146 ALARM DEVICE AREA_A CNTRL01 CNTRL01C01CH01 FAILED_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-04 11:49:28 1146 ALARM DEVICE AREA_A CNTRL01 CNTRL01C01CH01 MAINT_ALM INACT/ACK 07-ADVISORY OK <None>
SHP Office DeltaV 2018-10-04 11:49:28 1146 ALARM DEVICE AREA_A CNTRL01 CNTRL01C01CH01 ADVISE_ALM INACT/ACK 07-ADVISORY OK <None>
SHP Office DeltaV 2018-10-04 11:49:28 5790 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 FAILED_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-04 11:49:28 5793 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-04 11:49:28 5795 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 ADVISE_ALM INACT/ACK 07-ADVISORY OK <None>
SHP Office DeltaV 2018-10-04 11:49:26 2233 DOWNLOAD USER AREA_A CNTRL01 CNTRL01 UPDATE Administrator Start of Download - 0
SHP Office DeltaV 2018-10-04 11:49:26 3758 DOWNLOAD USER AREA_A CNTRL01 SYSTEM_DATA/DT UPDATE Administrator System node names, addresses
SHP Office DeltaV 2018-10-04 11:49:26 3991 DOWNLOAD USER AREA_A CNTRL01 SYSTEM_DATA/APT UPDATE Administrator System-wide setup data
SHP Office DeltaV 2018-10-04 11:48:54 8040 STATUS SYSTEM AREA_A PROPLUS PROPLUS OK 4-INFO Previous node status was: NO CONFIGURATION
SHP Office DeltaV 2018-10-04 11:48:53 410 ALARM HARDWARE AREA_A PROPLUS PROPLUS FAILED_ALM INACT/ACK 11-WARNING OK Node: Node not configured
SHP Office DeltaV 2018-10-04 11:48:53 410 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-04 11:48:53 410 ALARM HARDWARE AREA_A PROPLUS PROPLUS ADVISE_ALM INACT/ACK 07-ADVISORY OK <None>
SHP Office DeltaV 2018-10-04 11:48:52 4950 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator End of download. - 0
SHP Office DeltaV 2018-10-04 11:48:50 2800 DOWNLOAD USER AREA_A PROPLUS PROPLUS UPDATE Administrator Start of Download - 0
SHP Office DeltaV 2018-10-04 11:48:50 5300 DOWNLOAD USER AREA_A PROPLUS SYSTEM_DATA/DT UPDATE Administrator System node names, addresses
SHP Office DeltaV 2018-10-04 11:48:50 6540 DOWNLOAD USER AREA_A PROPLUS SYSTEM_DATA/MODT UPDATE Administrator Module names and node assignments
SHP Office DeltaV 2018-10-04 11:48:50 8420 DOWNLOAD USER AREA_A PROPLUS SYSTEM_DATA/APT UPDATE Administrator System-wide setup data
SHP Office DeltaV 2018-10-04 11:48:07 370 ALARM HARDWARE AREA_A PROPLUS PROPLUS FAILED_ALM ACT/UNACK 11-WARNING FAILED Node: Node not configured
SHP Office DeltaV 2018-10-04 11:45:19 2570 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-04 11:45:11 88 EVENT SYSTEM AREA_A PROPLUS JOUR ACTIVE 4-INFO
SHP Office DeltaV 2018-10-03 15:40:38 7700 CHANGE USER AREA_A PROPLUS LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:23:13 1980 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:21:49 2780 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:21:35 7216 CHANGE USER BOILER PROPLUS PC_AO1 Phoenix Contact Analogue out 1 PID1/OUT.CV ADMINISTRATOR NEW VALUE = 56.91
SHP Office DeltaV 2018-10-03 15:21:29 7180 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:20:43 1682 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO PC_FAULT_MODE.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 15:20:08 6380 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:20:08 6380 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:20:06 8680 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:14:00 4660 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:13:51 1960 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:13:00 1685 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 15:13:00 1686 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:59 6149 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:59 6670 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:59 8137 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:56 1674 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 15:12:56 1681 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:55 6147 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:55 6667 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:55 8137 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 15:12:00 4360 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:09:13 9260 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:09:10 8760 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 15:08:13 3686 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 AI1/APPLY_CONFIG_NOW.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 15:06:26 4650 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:41:04 9360 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:30:36 150 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:30:31 5850 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:22:27 630 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:22:25 3830 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:22:23 7630 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:15:45 930 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:15:30 330 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:14:40 9130 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:14:35 8630 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:05:25 4310 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 13:04:37 2610 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:57:04 7200 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:56:46 6500 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:56:36 1754 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:36 2282 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:36 3746 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:36 7291 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:56:36 7292 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:01 1737 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:01 2259 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:01 3725 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:56:01 7267 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:56:01 7275 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:50:31 1560 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:50:31 2085 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:50:31 3551 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:50:31 7094 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:50:31 7095 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:49:25 1527 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:49:25 2053 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:49:25 3516 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:49:25 7057 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:49:25 7063 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:49:02 1457 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = OPEN
SHP Office DeltaV 2018-10-03 12:48:55 9804 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:48:50 5300 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:48:37 4513 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO PC_FAULT_MODE.CV ADMINISTRATOR NEW VALUE = 2
SHP Office DeltaV 2018-10-03 12:47:50 1476 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:47:50 2002 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:47:50 3466 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:47:50 7007 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:47:50 7009 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:46:54 1447 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:46:54 1969 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:46:54 3435 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:46:54 6971 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:46:54 6978 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:46:11 418 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO PC_FAULT_MODE.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:45:56 6800 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:45:49 5133 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = CLOSE
SHP Office DeltaV 2018-10-03 12:45:44 1936 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-03 12:45:42 4700 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:45:27 1399 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:27 1927 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:27 3389 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:27 6931 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:45:27 6933 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:21 1395 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:21 1927 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:21 3382 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:45:21 6922 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:45:21 6929 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:44:06 590 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:43:55 1879 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-03 12:43:35 9767 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = OPEN
SHP Office DeltaV 2018-10-03 12:43:28 5441 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:42:14 1291 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:42:14 1820 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:42:13 5098 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:13 5187 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:13 5210 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:13 5238 CHANGE USER AREA_A PROPLUS CNTRL01 MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:13 6182 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-03 12:42:13 6824 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:42:08 1199 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:08 1214 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:42:08 3273 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:42:02 2702 CHANGE USER BOILER PROPLUS PC_AO1 Phoenix Contact Analogue out 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:42:02 2739 CHANGE USER BOILER PROPLUS PC_AO1 Phoenix Contact Analogue out 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:42:02 4281 ALARM INSTRUMENT BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:17 2190 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-03 12:41:05 1256 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:05 1781 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:05 3247 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:05 6146 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT IO: No Communications On Port - Serial Card, C05, P01
SHP Office DeltaV 2018-10-03 12:41:05 6789 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:41:05 6791 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:04 1255 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO Error Cleared Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:41:04 1256 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO Error Cleared Outputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:41:04 4251 EVENT PROCESS BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 ACTIVE 4-INFO Error Cleared Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:41:04 4252 ALARM INSTRUMENT BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:41:03 6762 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module ACTIVE 4-INFO Error Cleared Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:41:02 1990 STATUS SYSTEM AREA_A PROPLUS CNTRL01 BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-03 12:40:45 6133 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT IO: No Communications On Port - Serial Card, C05, P01
SHP Office DeltaV 2018-10-03 12:40:44 1245 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:43 1227 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO BUS_COUPLER_01/RL_DEV_STATUS Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 1234 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO BUS_COUPLER_01/RL_DEV_ONLINE Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 1242 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO BUS_COUPLER_01/STATUS_REG_7996 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 1248 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO ACTIVE 4-INFO BUS_COUPLER_01/STATUS_REG_7997 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 1253 EVENT PROCESS BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO EVENT_LIMITED. 4-INFO BUS_COUPLER_01/STATUS_REG_7996 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 1774 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:43 3237 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:43 4227 EVENT PROCESS BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 ACTIVE 4-INFO PC_AO1/REGISTER_IN Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:43 4239 ALARM INSTRUMENT BOILER CNTRL01 PC_AO1 Phoenix Contact Analogue out 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:42 6730 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module ACTIVE 4-INFO CNTR01_HOLD/DIGITAL_IN_0 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:42 6744 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module ACTIVE 4-INFO CNTR01_HOLD/BC01_AI1/REGISTER_0_IN Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:42 6750 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module ACTIVE 4-INFO CNTR01_HOLD/BC01_AI1/REGISTER_1_IN Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:42 6763 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module ACTIVE 4-INFO CNTR01_HOLD/BC01_AI0/REGISTER_01 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:42 6770 EVENT PROCESS BOILER CNTRL01 CNTR01_HOLD Controller 01 holding Module EVENT_LIMITED. 4-INFO CNTR01_HOLD/BC01_AI0/REGISTER_02 Inputs Transfer Failure
SHP Office DeltaV 2018-10-03 12:40:42 6797 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:40:42 6813 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:27 1234 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:27 1758 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:27 3227 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:40:27 6772 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:40:27 6774 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:39:54 6757 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:39:54 1218 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:39:54 1740 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:39:54 3208 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:39:54 6748 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:38:56 6719 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:38:56 6720 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:38:44 3021 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:38:43 2331 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:38:43 2349 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:38:43 5936 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:38:43 5952 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:38:43 6713 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:38:43 9333 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:38:42 8973 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:38:42 9067 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 12:37:49 8790 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:34:57 6090 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:34:21 90 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:32:31 1590 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:32:09 6501 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:32:09 6507 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:31:14 6990 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:29:45 1390 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 12:29:07 871 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:29:06 1735 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:29:05 5760 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-03 12:29:04 1380 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-03 12:29:04 1883 CHANGE USER AREA_A PROPLUS CNTRL01 MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:29:02 3880 CHANGE USER AREA_A PROPLUS PROPLUS MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:29:00 5137 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:29:00 6405 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:28:59 1396 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:28:58 2852 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:28:58 8008 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:28:57 3883 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 12:21:08 6141 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:21:08 6142 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:21:01 6135 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:21:01 6141 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:21:01 8592 EVENT PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG1/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:20:59 603 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:20:59 1124 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:20:59 2594 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:20:59 6135 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:20:59 6137 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:20:59 8596 EVENT PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 12:19:20 553 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:19:20 1078 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:19:20 2544 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:19:13 6076 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 12:19:13 6083 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 12:17:45 2260 STATUS SYSTEM AREA_A PROPLUS PROPLUS OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-03 12:17:41 5389 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 12:17:36 1360 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 12:17:32 572 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 12:17:30 2060 STATUS SYSTEM AREA_A PROPLUS PROPLUS BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-03 12:17:29 6060 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2018-10-03 12:17:27 5380 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 12:17:22 1360 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 12:17:14 561 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 12:17:14 8560 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2018-10-03 11:23:15 1760 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 11:23:14 1695 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 11:23:14 1766 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 11:23:14 4283 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 11:23:14 4772 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 11:23:14 8466 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 11:22:38 4264 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 11:22:38 4268 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 11:22:13 4250 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 11:22:13 4257 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 11:21:03 786 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 AI1/LO_LO_LIM.CV ADMINISTRATOR NEW VALUE = 30
SHP Office DeltaV 2018-10-03 11:20:56 6144 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 AI1/LO_LIM.CV ADMINISTRATOR NEW VALUE = 50
SHP Office DeltaV 2018-10-03 11:20:43 7504 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 AI1/HI_LIM.CV ADMINISTRATOR NEW VALUE = 200
SHP Office DeltaV 2018-10-03 11:20:36 4780 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 AI1/HI_HI_LIM.CV ADMINISTRATOR NEW VALUE = 240
SHP Office DeltaV 2018-10-03 11:20:23 444 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALM_DESC_LOLO.CV ADMINISTRATOR NEW VALUE = Close Site Demand Valve
SHP Office DeltaV 2018-10-03 11:19:52 4390 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALM_DESC_LO.CV ADMINISTRATOR NEW VALUE = Reduce Site Demand
SHP Office DeltaV 2018-10-03 11:19:37 381 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALM_DESC_HIHI.CV ADMINISTRATOR NEW VALUE = Close Well Down
SHP Office DeltaV 2018-10-03 11:19:25 7181 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALM_DESC_HI.CV ADMINISTRATOR NEW VALUE = Open Bypass
SHP Office DeltaV 2018-10-03 11:18:14 2002 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = CLOSE
SHP Office DeltaV 2018-10-03 11:18:05 9203 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = OPEN
SHP Office DeltaV 2018-10-03 09:45:36 5687 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 09:45:26 5682 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 09:29:54 8473 CHANGE USER BOILER PROPLUS PC_AO1 Phoenix Contact Analogue out 1 PID1/OUT.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:29:48 4693 CHANGE USER BOILER PROPLUS PC_AO1 Phoenix Contact Analogue out 1 PID1/OUT.CV ADMINISTRATOR NEW VALUE = 25
SHP Office DeltaV 2018-10-03 09:29:40 3276 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = CLOSE
SHP Office DeltaV 2018-10-03 09:29:39 5623 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-03 09:29:35 2392 CHANGE USER BOILER PROPLUS XV110 Well Head Valve DC1/SP_D.CV ADMINISTRATOR NEW VALUE = OPEN
SHP Office DeltaV 2018-10-03 09:29:31 4730 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:29:31 4781 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:29:31 5617 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-03 09:29:31 7689 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:29:31 7707 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:29:24 7901 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:29:21 5503 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:29:19 5984 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:29:10 5616 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:29:04 5605 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-03 09:27:10 9905 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-03 09:27:09 1907 CHANGE USER AREA_A PROPLUS CNTRL01 MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:27:04 1400 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM INACT/ACK 11-WARNING OK <None>
SHP Office DeltaV 2018-10-03 09:27:02 6500 CHANGE USER AREA_A PROPLUS PROPLUS MAINT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:58 4728 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:58 4750 CHANGE USER BOILER PROPLUS PC_DI2 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:26:58 6994 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:26:55 5007 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:26:54 5931 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:54 5953 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:26:54 9044 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:26:54 9060 CHANGE USER BOILER PROPLUS BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:48 209 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 PV_BAD.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:48 224 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:26:48 2734 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:26:48 5534 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:26:46 536 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/ACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:26:45 4376 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-03 09:26:45 4499 CHANGE USER BOILER PROPLUS ANALOG2 Phoenix Contact Analogue 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-03 09:23:45 440 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 09:23:45 442 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:44 4906 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:44 5431 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:44 6894 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:22 418 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 09:23:22 425 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:21 4890 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:21 5412 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:21 6881 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:04 2867 EVENT PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG1/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 09:23:02 416 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 09:23:02 417 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:02 2873 EVENT PROCESS BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 ACTIVE 4-INFO Error Cleared I/O Input Failure
SHP Office DeltaV 2018-10-03 09:23:01 4879 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:01 5402 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:23:01 6870 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD INACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:21:37 366 EVENT PROCESS BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 ACTIVE 4-INFO ANALOG2/AI1/ALM1 I/O Input Failure
SHP Office DeltaV 2018-10-03 09:21:37 373 ALARM INSTRUMENT BOILER CNTRL01 ANALOG2 Phoenix Contact Analogue 1 PVBAD_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:21:36 4834 ALARM INSTRUMENT BOILER CNTRL01 BUS_COUPLER_01 Phoenix Contact Remote IO FAULT_ALM ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:21:36 5360 ALARM INSTRUMENT BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:21:36 6827 ALARM INSTRUMENT BOILER CNTRL01 PC_DI2 Phoenix Contact Digital in 1 PV_BAD ACT/UNACK 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-03 09:07:44 2170 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-03 09:07:42 1570 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-03 05:59:45 8325 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 05:59:43 8324 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 05:21:30 7078 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 05:21:26 7076 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 03:28:26 5300 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-03 03:28:11 5000 STATUS SYSTEM AREA_A PROPLUS CNTRL01 BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-03 03:28:09 8188 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 03:28:00 3370 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 03:27:53 8181 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-03 03:27:50 3364 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 02:12:20 898 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-03 02:12:19 898 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 22:33:38 8562 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 22:33:24 3740 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 22:33:22 8551 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 22:33:20 3738 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 21:57:38 7379 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 21:57:23 7559 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Device Connection Failure - PROPLUS
SHP Office DeltaV 2018-10-02 21:22:29 1922 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 21:22:28 1419 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 20:49:11 2180 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-02 20:48:52 5138 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 20:48:50 1380 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 20:48:44 826 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 20:48:43 9980 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Primary ACN - CNTRL01
SHP Office DeltaV 2018-10-02 20:48:41 1780 STATUS SYSTEM AREA_A PROPLUS CNTRL01 BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-02 20:48:38 5131 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 20:48:36 1380 ALARM HARDWARE AREA_A PROPLUS PROPLUS MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 20:48:25 310 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 20:48:25 980 EVENT SYSTEM AREA_A PROPLUS ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - CNTRL01
SHP Office DeltaV 2018-10-02 20:15:03 4217 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Device Connection Failure - PROPLUS
SHP Office DeltaV 2018-10-02 18:06:02 3880 STATUS SYSTEM AREA_A PROPLUS CNTRL01 OK 4-INFO Previous node status was: BAD INTEGRITY
SHP Office DeltaV 2018-10-02 18:05:51 9839 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 18:05:47 3680 STATUS SYSTEM AREA_A PROPLUS CNTRL01 BAD INTEGRITY 4-INFO Previous node status was: OK
SHP Office DeltaV 2018-10-02 18:05:38 2519 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 18:05:37 9830 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 18:05:36 5018 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 17:34:03 1502 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 17:33:58 4001 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 17:02:37 7804 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM INACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 17:02:28 487 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Primary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 17:02:21 7797 ALARM HARDWARE AREA_A CNTRL01 CNTRL01 MAINT_ALM ACT/UNACK 11-WARNING MAINT ACN Communications: Not Communicating - Primary Network
SHP Office DeltaV 2018-10-02 17:02:17 2981 EVENT SYSTEM AREA_A CNTRL01 ACN COMM ACTIVE 4-INFO Switched to Secondary ACN - PROPLUS
SHP Office DeltaV 2018-10-02 16:50:40 3060 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:50:18 3054 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:50:17 3784 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:50:17 3809 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:50:17 6862 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:50:17 6879 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:50:12 4651 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:49:52 3034 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:49:27 5088 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:24:01 1325 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:24:01 1364 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:24:01 2204 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:24:01 5028 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:23:48 9156 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:23:43 2192 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:23:31 2179 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:23:18 8425 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:23:15 1221 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:23:15 2104 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:23:15 2182 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:23:14 5299 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:23:14 5338 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:23:12 6360 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:23:10 460 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:23:03 2172 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:22:53 2166 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:22:31 2985 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:19:04 567 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:19:04 607 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:19:04 2041 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:19:04 4116 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:19:04 4135 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:18:59 2039 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:18:52 2034 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:18:48 2034 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/UNACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:18:41 2030 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:17:47 2297 CHANGE USER BOILER PROPLUS ANALOG1 Phoenix Contact Analogue 1 PVBAD_ALM.ENAB ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:17:47 9462 ALARM INSTRUMENT BOILER CNTRL01 ANALOG1 Phoenix Contact Analogue 1 PVBAD_ALM DISABLED 15-CRITICAL IOF General I/O Failure
SHP Office DeltaV 2018-10-02 16:17:25 1094 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DI1/SIMULATE_D.ENABLE ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:17:25 1988 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM INACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:15:56 1315 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:15:56 1501 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:15:56 1937 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/ACK 11-WARNING DI_ALM Tripped
SHP Office DeltaV 2018-10-02 16:15:56 4839 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DISC_ALM.NALM ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:15:56 4857 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ALARMS.MACK ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:14:32 6186 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:14:29 6440 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:14:26 651 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:11:59 9160 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:11:34 160 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:10:54 2160 CHANGE USER AREA_A PROPLUS REMOTE LOGOFF ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:10:46 446 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 0
SHP Office DeltaV 2018-10-02 16:10:37 3578 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 ENABLED.CV ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:10:27 1960 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 completed successfully
SHP Office DeltaV 2018-10-02 16:10:27 3260 CHANGE USER AREA_A PROPLUS REMOTE LOGON ADMINISTRATOR
SHP Office DeltaV 2018-10-02 16:10:18 1763 ALARM PROCESS BOILER CNTRL01 PC_DI1 Phoenix Contact Digital in 1 DISC_ALM ACT/UNACK 11-WARNING DI_ALM Normal
SHP Office DeltaV 2018-10-02 16:10:17 4179 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DI1/SIMULATE_D.SVALUE ADMINISTRATOR NEW VALUE = 1
SHP Office DeltaV 2018-10-02 16:10:15 1934 CHANGE USER BOILER PROPLUS PC_DI1 Phoenix Contact Digital in 1 DI1/SIMULATE_D.ENABLE ADMINISTRATOR NEW VALUE = 2
SHP Office DeltaV 2018-10-02 16:10:12 6660 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 started
SHP Office DeltaV 2018-10-02 16:10:10 2160 EVENT SYSTEM AREA_A PROPLUS COLD_RESTART DOWNLOAD 4-INFO Cold restart on CNTRL01 completed successfully